Anti-Foaming Energy Conservation System:
The AFEC technology developed by the N.E.P. engineering team offers a
unique safety and energy conservation management of expensive boiling
water and steam.
The AFEC system is made of a mass measuring water sensor, anti-foam
sensor,
electronic high temperature sensor, interactive LCD display and
microprocessor
controller.
The AFEC system is unique because:
The water sensor cannot be falsely triggered by foam formation
on
the top of the boiling water. This eliminates the problem of
heating elements burning out in free air.
The additional foam-sensing probe, which is unique to our
design,
would automatically initiate a drain cycle upon foam formation.
Unlike other humidifiers, the drain can be initiated only when
necessary without having continuous skimming to drain expensive boiling
water. This is
an excellent energy conservation measure.
The SK300 is unique in having fast actin electronic safety
temperature sensors inside the steam container in very close proximity
to the heating elements. Other humidifiers use only a bimetallic
external electro-mechanical temperature switch (which is also standard
on all SK300s). Therefore, the AFEC system provides an additional
layer of protection.
|